دانلود نرم افزار Elite RHVAC v8.01.217 With Manual D Ductsize
Features
.: Calculates peak heating and cooling loads in accordance with Manual J.
.: Calculates Duct Sizes, System Losses, and fan static pressure requirement in accordance with Manual D. Lets you enter the entire duct system, or only the path(s) with the highest pressure loss if you prefer.
.: Determines building tonnage and room CFM requirements.
.: Incorporates Manual J Addenda A, B, C, and D!
.: Links to REM/Rate, Architectural Energy Corporation\'s popular home energy rating tool.
.: Links to REScheck, DOE\'s energy codes program.
.: Links to the Energy Gauge USA home energy rating program.
.: New! Generates a Building Rotation report that shows you tonnages and room CFM requirements at each rotation.
.: New! Includes a Buiding Rotation Duct Size Preview window that shows you the heating and cooling CFM for each room or duct in the project for each rotation of the building, as well as the maximum duct size of all rotations.
.: Calculates hydronic radiant floor tubing length required.
.: Follows ACCA Manual J, 8th Edition. Rhvac is approved by ACCA.
.: Computes room by room, zone, system & building.
.: Calculates from manually entered data or directly from floor plans created with Drawing Board (sold separately).
.: Rooms and zones can be assigned to 15 systems.
.: Allows 1000 rooms grouped into 10 zones per system using drag and drop zoning techniques.
.: Allows 20 walls, 20 windows, 8 roofs, 6 floors and 6 doors per room.
.: Allows custom construction materials and descriptions.
.: Lets you specify lists of \"Favorite\" materials so you can select them easier.
.: Remembers your most recent material selections so you can reselect them easily.
.: Looks up HTM & U-values or lets you specify them.
.: Determines Adequate Exposure Diversity status.
.: Links to Ductsize, Energy Audit and PsyChart. The PsyChart program can import Rhvac system data directly into its Air Handler Model window.
.: No copy protection!
.: Displays psychrometric chart.
.: Lets you select equipment from ARI and GAMA databases.
.: Prints exploded color pie charts, bar graphs, and custom sales proposals.
.: Allows decimal feet, feet-inches or metric length and width dimensions.
.: Allows exterior shading (overhangs and offsets).
.: Provides inputs for summer & winter partition temperature differences
حجم : 25 مگابایت
دانلود : فول برنامه + ریجستر
http://rapidshare.com/files/41071787/Rhvac8.01.221.rar
دوستان دانلود از سایت راپید شیر باید اول صفحه باز شود و بر روی گزینه Free در جدول کلیک کنید پس از آن صفحه جدیدی باز میشود و باید علامت ها را در داخل باکس قرار دهید و دانلود کنید
معرفی : engineercivil.mihanblog.com
Calculation Method
The Rhvac Program follows the exact methodology described in the Air Conditioning Contractors of America (ACCA) Manual J, Eighth Edition entitled "Residential Load Calculation". Elite Software is a technical software partner for ACCA; the Rhvac program is approved by ACCA.
Powered By ACCA Manual J
The recently released 8th edition of Manual J is a significant expansion over the 7th edition. There are numerous changes, but the most noticeable is a much larger list of built-in floor, roof, wall, glass and door materials. The 7th edition was missing references to current popular materials such as structurally insulated panels, insulated concrete forms, logs, and much more. The 8th edition includes all these materials plus all common building materials with hundreds of variations. This writer's opinion is that the roof, wall, and glass loads tend to calculate slightly lower in MJ8 compared to calculations made with MJ7 and attempting to equalize all other factors.
Duct gains and losses are another area much changed in the 8th edition. Many more scenarios of duct system type, duct location, insulation values, temperatures, etc. are considered in the 8th edition. Generally speaking, duct gains and losses calculated using MJ8 procedures will be larger than what was calculated using MJ7 procedures.
MJ8 also introduced several new concepts including adequate exposure diversity (AED) , average load procedure plus excursion method, and the peak fenestration gain method. If an area of a building served by a single hvac system is deemed to not have AED, that entire area is considered to have an "excursion," which means that an additional sensible gain load is automatically added at the system level.
In summary, the new MJ8 hvac calculation procedures are the state of the art in hvac design. The MJ8 procedures provide higher accuracy than the MJ7 procedures, and perhaps even more importantly, they provide far greater flexibility in analyzing modern building construction materials and techniques.
Up to Date with the latest Manual J changes (Addenda A, B, C and D)
Rhvac now incorporates the changes in each of the recently published addenda for Manual J.
-- Addendum A: The Rhvac Help window now includes the list of "Do's and Don'ts" from this addendum. You can access the list by clicking the menu "Help | Manual J Do's and Don'ts."
-- Addendum B: Uses the Hourly Fenestration Gain (HFG) procedure for room level loads whenever you have rooms in multiple zones within the same system. Also includes System Concept Warnings whenever a system has "excursion" as a result of not having adequate exposure diversity.
-- Addendum C: Gives you much more control over duct loads and has an easier to understand and more flexible set of inputs to let you define the properties of your duct system more precisely. Allows for separate supply and return characteristics, as well as multiple duct location scenarios within the same system. Now you only need to enter one set of duct properties at the system level, instead of having to enter duct properties for each room.
-- Addendum D: Includes more options to let you define the envelope construction tightness when determining infiltration. Also has a more accurate methodology of accounting for the effect of fireplaces on infiltration.
Update Information
Users of existing versions of Rhvac can upgrade to the latest version of Rhvac, supporting ACCA Manual J 8th edition, for a substantial discount over full purchase price. If you have Rhvac version 6, you can still download for free the final release of Rhvac 6.08, which incorporates a number of useful improvements.
New Features in Version 8
Here's a list of the new features that version 8 has that were not in version 6. If you want to see the benefits of upgrading from Rhvac 6 to Rhvac 8 before you buy, the version 8 functional demo can co-exist with existing versions of Rhvac 6. Click the download link at the top of the page to download the fully functional demo for Rhvac version 8.
Duct Static Pressure Loss Calculator window calculates duct sizes and the static pressure losses of your duct system. You can either enter your entire duct system, or just enough to calculate the fan static pressure requirement (one single route, or "path"). This unique tool includes a powerful Fitting Selector dialog, which makes it easy to select from hundreds of fittings from ACCA's Manual D.
:: Includes link to REM/Rate, Architectural Energy Corporation's popular home energy rating tool. Saves you time by creating a file to transfer building component and other data to version 11.4 or higher of REM/Rate.
:: Links to REScheck, DOE's energy codes program. Creates a new REScheck project file, with information such as R-values and areas already filled in for each building component.
:: Includes an updated link to Florida's EnergyGauge Fla/Res program for Florida Energy Code compliance and Florida Home Energy Rating System (HERS) calculations.
:: Greatly expanded material lists for roofs, walls, and windows.
:: Supports Favorite, Recent and Custom Materials as well as a global material database.
:: Support for new glass and window properties, including insect screen, ground reflectance and more.
:: Allowance for hot water piping losses. Lets you enter the characteristics of the hot water distribution pipe in order to calculate its sensible loss.
:: Accounts for heat recovery units and reduced fresh air loads.
:: Extensive new duct gain and loss factors for all types of scenarios. Allows you to precisely specify the characteristics of the duct system in order to more accurately determine its sensible gain and loss. Now includes latent gain due to the ductwork as well.
:: New option to calculate winter humidification requirements. Allows you to specify an indoor relative humidity in the winter in order to calculate the required gallons per day of water to be added, as well as the sensible loss due to the device.
:: Psychrometric Chart Graphical Report: Displays each point in the cooling process on an altitude-adjusted chart.
:: New exhaust options to accurately predict fresh air requirements.
:: Blower Power Sensible Gain: When the cooling equipment's rated capacity does not account for the heat gain due to the blower motor and fan, this input allows you to directly enter the wattage of the blower as a supply side load.
:: Adequate Exposure Diversity Check: An hour-by-hour calculation is done on the glass sensible gain to determine if the system meets the criteria for Manual J's Adequate Exposure Diversity test.
:: Adequate Exposure Diversity Test Graphical Report: Shows you the hourly glass load in order to let you see how far the peak deviates from the average.
:: A functional demo of Drawing Board is built into this version of Rhvac. The built-in demo version of Drawing Board allows you to draw and save floor plans of unlimited size, but HVAC calculations can only be made for three rooms of the floor plan.
Download : (25681 KB)
Pass : www.softarchive.net